4" IL Firestop Spacer
In stock
SKU
ILFS04
- Twin Lined System
- Air Gap insulated
- Aluminium Lined
- Zalutite Outer Casing
- Strong rigid System
4" IL Firestop Spacer
Used at floor or ceiling penetration or in conjunction with the Support Plate to maintain the required clearance to combustible materials.
- Twin Lined System
- Air Gap insulated
- Aluminium Lined
- Zalutite Outer Casing
- Strong rigid System
Designation: | BS EN 1856-1: T250 N1 D VmL11030 0(50) |
---|---|
Construction | Aluminium liner protected by an outer casing of Zalutite |
Warranty | 5 years |
Fuel Type | IL gas vent is suitable for gas appliances, typically in domestic or small commercial installations |
Suitable For Condensing | No |
Component Type | Fire Stop/Cover Plates |
Building Regulations | Document J |
Installation Guide: | Where the vent passes through a floor or ceiling without support, a Firestop Spacer must be used on both sides of the penetration to provide a barrier to fire and maintain a minimum 50mm (2in) air gap clearance to combustible materials. If the Gas Vent is required to be supported where it penetrates the floor/ceiling Support Plates should be applied. These square heavy gauge galvanised plates must be fixed through the corner holes on top of the floor joist or slab through which the chimney is passing. The flanged collar is clamped to the vent so that the lower flange rests on the support plate. A Firestop Spacer must be used on the underside of the opening at ceiling level. The MAXIMUM height that can be supported, including any suspended lengths, is 18m (60ft). The combination of lengths and fittings used should be such that no joint occurs within the floor space. |