6" 5° - 30° Roof Flashing

In stock
SKU
ILFL106
  • Twin Lined System
  • Air Gap insulated
  • Aluminium Lined 
  • Zalutite Outer Casing
  • Strong rigid System

6" IL 5° - 30° Flashing

Used together with a storm collar to provide a weather proof seal where the IL system passes through the roof.

  • Twin Lined System
  • Air Gap insulated
  • Aluminium Lined 
  • Zalutite Outer Casing
  • Strong rigid System
Specifications
Designation: BS EN 1856-1: T250 N1 D VmL11030 0(50)
Construction Aluminium liner protected by an outer casing of Zalutite
Fuel Type IL gas vent is suitable for gas appliances, typically in domestic or small commercial installations
Suitable For Condensing No
Component Type Roof Flashings
Building Regulations Document J
Installation Guide: Position the flashing over the projecting IL Vent, and flash to the tiles or slates as appropriate. Fix the Storm Collar over the Flashing and seal the joint with the silicone sealant provided.

Please Note: If a lead flashing is used, make sure that the seal is thoroughly made so that the risk of moisture influenced corrosion cannot occur where the lead touches the outer skin.

Rubber Flashings can also be used with IL Gas Vent.